Powered By

Free XML Skins for Blogger

Powered by Blogger

Friday, August 22, 2008

Deltas Not Working for Installation Master Data BW Errors

I am having trouble with the deltas for master data object "installation". The changes are clearly recorded in the time dependent and time independent tables, EANL/EANLH. The delta update mode is using ALE pointers, does anyone know of a table where I can go check where these deltas/changes are temporarily stored, or what's the process behind this type of delta?

The following steps must be executed:

1. Check, whether the ALE changepointer are active in your source system (Transaction BD61) and whether the number range is maintained (Transaction BDCP).
2. In addition, check in the ALE Customizing, whether all message types you need are active (Transaction SALE -> Model and implement business processes -> Configure the distribution of master data -> Set the replication of changed data -> Activate the change pointer for each message type ).
3. Check, whether the number range for the message type BI_MSTYPE is maintained (Transaction SNUM -> Entry 'BI_MSTYPE' -> Number range -> Intervals). The entry for 'No.' must be exactly '01'. In addition, the interval must start with 0000000001, and the upper limit must be set to 0000009999.
4. Go to your BW system and restart the Admin. workbench.
All of the following activities occur in the InfoSource tree of the Admin. Workbench.
5. Carry out the function "Replicate DataSource" on the affected attached source system for the InfoObject carrying the master data and texts.
4. Activate the X'fer structure
All changes, all initial data creations and deletions of records from now on are recorded in the source system.
5. Create an InfoPackage for the source system. In the tabstrip 'update parameter', there are three alternative extraction modes:
Full update
Delta update
Initialization of delta procedure
First, initialize the delta procedure and then carry out the delta update.

An update on this issue:

In the EMIGALL process, SAP decided to bypass all the standard proces to update the delta queues on IS-U, because it would cause too much overhead during the migration. It is still possible to modify the standard programs, but it is not recommended, except if you want to crash you system.

The other options are as follows :
- Extract MD with full extractions using intervalls..
- modify the standard to put data in a custom table on which you are going to create a generic delta;
- modify the standard to put the ALE pointers in a custom table and then use a copy of the standard functions to extract these data....
- Extract the data you want in a flat file and load it in BW...

By the way, if you want to extract the data from IS-U, forget to do it during migration, find another solution to extract after.

PS: Well if you have generic extractor and huge volume data then you can do it with multiple INITS with RANGES as selection criteria and then a single DELTA(which is summation of all INITS) in order to improve performance with GENERIC DELTA.

No comments: